8 Reasons demonstrating that upgrading to Versiv™ will “Cut Your Certification Cost by 65%"

REASON #7A why upgrading to Versiv™ will cut your certification costs:
"EXTENDED TESTS: TCL &
SHIELD INTEGRITY"
Measuring TCL was previously only possible with laboratory equipment. Evidence is accumulating proving that failed TCL may cause 1GBASE-T and 10GBASE-T to malfunction, even when all other transmission parameters provide good margins above the standard limits.








SHIELD INTEGRITY TEST
EMI gets significantly worse if the shield is open (floating) at one end.
TCL
Shows you how well the impedances of the pair's conductors are balanced. Likely to be included in future field test requirements. Specified in ANSI/TIA-568-c-2 & TSB's & ISO/IEC 11801:2010.

REASON #7B why upgrading to Versiv™ will cut your certification costs:
"EXTENDED TESTS: RESISTANCE UNBALANCE"
PoE operation at maximum load is at risk if Resistance Unbalance is not compliant.



UNBALANCE BETWEEN PAIRS
While PoE devices can tolerate some DC resistance unbalance, too much unbalance causes saturation of the transformer, which can cause Ethernet data signals to become distorted.
OPTIONAL TEST
Not yet required for field testing, but specified in IEEE 802.3af and 802.3at ANSI/TIA-568-C.2 and ISO/IEC 11801:2010.


REASON #8 why upgrading to Versiv™ will cut your certification costs:
"NEW LINKWARE LIVE AFFILIATE PARTNERS"
Leading companies worldwide have affiliated with Fluke Networks to leverage the ability of LinkWare Live to streamline the cabling installation and certification process. Typically 3.2 hours per 1000 links are wasted manually editing Cable ID's in reports that don't match the specs.

LABELLING DONE RIGHT FIRST TIME WITH LINKWARE LIVE AND OUR PARTNERS.
Define cable IDs and test setting from your PC or tablet, then send them to the testers or labelers at the jobsite for mistake-free testing.